Heat & Smoke 2 in 1 Detector Tester -CC06

$ 675.00 USD
- +
icon-bag Add to Cart
Home

HEAT & SMOKE 2 IN 1 DETECTOR TESTER

Too lazy too read?

Contact our staff Caysie for any question.

Messenger/LinkedIn/Twitter


※CAUTION※

※RISK OF ELECTRIC SHOCK UNDER STORMY WEATHER AND EXPOSED WIRES ENVIRONMENT※
※RISK OF FIRE UNDER GALE ENVIRONMENT※

Functions:

Combine smoke detector tester and heat detector tester in one device, our Heat & Smoke 2 in 1 Detector Tester is suitable for most detectors. Air is heated by the heater within the cup rapidly. Smoke dispensed to stimulate the sensing chamber rapidly by light press or pulling rope.

Upgraded mistake-proofing body design to avoid smoke detector tester spray from falling over. Pulling rope provided for testing smoke detectors located on light ceiling boards (T-bar ceilings).


Features:

-    Suitable for both smoke detectors and heat detectors. Test different types of detectors with one device.
-    Design for using at height and at angles.
-    Available to install CCFireTester Auto Smoke Clearing Fan, upgrade the tester with clearing mode.

 For Smoke Testing:

  1. Upgraded mistake-proofing body design to avoid smoke detector tester spray from falling over.
  2. Able to hold Japan, US and UK made smoke tester spray.
  3. Available to add pulling string. Testing complete effortlessly even for detectors on light ceiling boards.

For Heat Testing:

  1. Stainless upper cup with well durability and is designed for efficient convection.
  2. Quick-lock design prevent the heater from moving and can set up the heater easily.
  3. Heater activate and inactivate rapidly.
  4. Heater won't damage the detector.
  5. Nohmi/Panasonic heater available.

STANDARD EQUIPMENT

1.  Heat & Smoke 2 in 1 Detector Tester * 1

2.  Heater * 1

3.  Heater Cover * 1

4.  Instruction manual *1

5.  All-Purpose Adapter for Extension Poles *1


SPECIFICATION

Heat & Smoke 2 in 1 Detector Tester - Model CC06V3

Material: Stainless Steel, Polycarbonate, ABS (Acrylonitrile Butadiene Styrene)

Stainless Upper Cup: Inner Dia.89±1mm, outer Dia.94±1 mm, thickness 2.6±1mm

Total Height: 204~265.1±1 mm

Weight: approx.: 573g±1

Oil Cup Volume: 40cc ±1 (2 hours usage)

Fuel: Cleaning Naphtha

Maximum Temp.: approx. 240℃/464℉

All-Purpose Adapter for Extension Poles: 49g


ADDITIONAL INFORMATION

  1. This product is highly electrical conductive

  2. Excessive fuel (cleaning naphtha) might lead to fire during usage, kindly remove excess fuel by upside down the fuel cup.

  3. Make sure the fuel cup is plugged-in properly. Improper placement might lead to fuel cup fall off.

  4. Make sure the gas ejection pipe on the oil cup has been installed properly.
    Improper placement might lead to pipe deformation or damage.

  5. Do not place or store fuel and lighter under high temperature environments or in vehicles.

  6. Do not rub, touch or pour liquid on the heaters’ fabric surface.
    Improper usage of Heater might lead to invalidation. 

  7. Avoid using the Heat & Smoke 2 in 1 Detector Tester  in wire-exposed environment and under stormy weather.

  8. Avoid using the Heat & Smoke 2 in 1 Detector Tester under windy or gale environments.

  9. Please equip with workplace safety equipment or personal protective equipment (e.g. Safety Helmet)when using the detector tester.

APPLICATION

For Smoke Testing only:
Before Inspection:

  1. Screw out the lower cup (Grey color)

  2. Place the smoke detector tester in the lower cup and screw in.

  3. Adjust the pressure for smoke detector testing, it should spray out smoke easily by a slight press.

  4. Make sure the gas ejection pipe on the oil cup has been placed properly.

  5. Plug-in the Heat & Smoke 2 in 1 Detector Tester to the extension pole.

  6. Start Inspection.

After Inspection:

  1. Screw out the lower cup.


For Heat Testing only:

Before Inspection:

  1. Add 50cc fuel to the oil cup, remove excess fuel.

  2. Plug-in the fuel cup.

  3. Make sure the gas ejection pipe on the oil cup has been placed properly.

  4. Make sure the heater is inserted.

  5. Push the moveable heater plate to "OPEN"

  6. Ignite the heater.

  7. There will be no flame occurred and the heaters' fabric should combust when ignited successfully.

  8. Air will be heated up rapidly within the cup.

  9. Install the Heat & Smoke 2 in 1 Detector Tester to the extension pole.

  10. Start Inspection.

After Inspection:

  1. Put the heater cover on the Heater for at least 1 minute.

  2. Heaters’ fabric should be in non-combustion status.
    If the heaters' fabric keep on combusting, kindly unplug the oil cup.


For Heat & Smoke Testing:

Before Inspection:

  1. Follow with the procedure of "Heat testing" #1 ~ #8

  2. Confirmed the heater is properly heated up with no flame occured.

  3. Follow with the procedure of "Smoke testing" #1~4

  4. Install the Heat & Smoke 2 in 1 Detector Tester to the extension pole.

  5. Start Inspection.

After Inspection:

  1. Screw out the lower cup.

  2. Put the heater cover on the Heater for at least 1 minute. 

  3. Heaters' fabric should be in non-combustion status.
    If the heaters; fabric keep on combusting, kindly unplug the oil cup.
     

TROUBLESHOOTING

Condition ONE: Heated up Temperature too low.

  1. Movable cover plate has not push to the "OPEN" line properly.

  2. Not enough fuel.

  3. Oil cup cannot fixed to the tenon.
    This situation usually occurs when the oil cup is used to refill fuel frequently, please press the oil cup and shape it to fixed to the tenon.

  4. Oil cup cotton volume is too small to reach the bottom of the heater;
    Oil cup cotton is carbonized due to frequent usage.
    Kindly tear the carbonized part or change/fill up the cotton.

  5. The Heater has absorbed too much the smoke testers' smoke.
    Please burn the heater by its bottom until no more smoke occurs.
    If it is still not working, the heater should be at the end of the lifespan, please replace it with a new one.


Condition TWO: Smoke Detector Tester spray out smoke continuously 

  1. The lower cup screws too much, pressure is too high for the smoke detector tester. Kindly screw out the lower cup.

  2. Detector Tester's holder is deformed, kindly uninstall the holder and shape it back. (Reminded not to screw the holders' screw too tight.)

  3. Oil cup was not fixed to the tenon.
    Please press the oil cup and shape it to be fixed to the tenon.

  4. The gas ejector pipe on the oil cup has not been installed properly.

COMPARISON CHART



CCFireTester CC06Testifire 1000
Tester Basic Info.Price(USD)
$350
$1112
*Price fluctuate, its the lowest price we found.
Material of SmokeCanned Smoke
Smoke Capsule
Weight573g
1140g
Available angle
free angle
specific angle
Structure & Maintenance
simple mechanic structure, no need to matainence
electric & software module,
might require update

Material & Durability
standless steel & ABS material, simple mechanic structure, heat-resisting, drop proof
electric module and plastic
Width of testing cup(mm)
89
125
Get Ready
1. add oil & light up the heater.
2. put the aerosal spray in.

1. install battery & smoke catridge.
2. set up testing sequence.

Using
No limit in testing sequence.
Press for smoke spraying or
Get close to heat up the detector.

Spray smoke and heat up in set sequence.
Smoke TestingAdjustable Tester Spray
Japan made, Solo,
CCFiretester 250ml & 150ml and other

specific smoke catridge
Available to test
1000 detectors
(with CCFireTester Canned Smoke)

?
Smoke Clearing
Available with CCFireTester
Auto Smoke Clearing Fan

with clearing mode
Clearing Efficiency
Clear out smoke right away after testing
Take off for standby mode then wait for 2 sec
and put it back for blowing out.

Storage temp. of the aerosol
lower than 40°C
lower than 100°C
Heat TestingDurability/Endurance of heater
4360 hours
?
Output Temperature
340°C(290°C in 22 sec)
100°C
Material of heat
Flame Retardant Fabric Heater
Battery batons, needs to be charged before testing
Record number of tested detectors

X
v
Certification

X
UL listed
Potential Danger

may burn up if added too much fule
safer, but heat up slower
Conductivity

conductive
Non-conductive

Other FunctionUpgrade with clearing mode with Auto Smoke Clearing Fan

Quotation & Inquiry

Due to high order volume, inquiry responses are temporarily paused. We prioritize processing paid orders through our website. Please use our checkout system for pricing estimates. For addresses outside the coverage area, kindly email us. Thank you!

Addional information:

  1. Manufacturer name:CHANGCHI SECURITY EQUIPMENT CO. LTD.
  2. Brand name:CCFireTester.
  3. Lead time:about 10-13 working days after payment confirmed, excluding customs processing time.
  4. Country of origin:all of our products are made in Taiwan.
  5. Data sheet:we describe out product detailedly on our website, you can directly print the product page as the data sheet.
  6. Certification:our products are currently uncertified.
  7. We sending products from:No.11, Lane 227, Ren-Ai Rd., West Dist., Chia-Yi City , Zip 60055, Taiwan
  8. Warranty:Products are out of warranty when sold overseas.